Con-Vents® Products are made in the USA by a US Veteran
  • Home
  • Styles & Prices
  • Useful Tips
  • Our Story
  • Get In Touch
  • Home
  • Styles & Prices
  • Useful Tips
  • Our Story
  • Get In Touch
Search by typing & pressing enter

YOUR CART

Con-Vents® Products 

Container Vent Kit
Outer Rib Mount Vent
Inner Rib Mount Vent
Door Mount Vent
Installation Template
Bulk Purchasing
All prices include shipping.
Shipping to USA only. CA residents add sales tax.
CONTAINER VENT KIT
​
Style #52957-K
​Patent Pending
Indicate Quantity in Cart
To achieve cross flow ventilation through your container you will need a minimum of (2) two vents. A single vent, including a roof mounted vent such as a Wind Turbine, will not provide the necessary flow through ventilation. For hot air to escape your container, cooler air must be able to enter the container to replace the exhausted hot air.

For these reasons we offer a CONTAINER VENT KIT, at a reduced cost, which includes two of our most popular Vent, the Outer Rib Mount Style 52957-O (shown and described below), to provide everything you need to achieve flow through ventilation.

This kit includes (2) complete vents with mounting hardware, an Instruction Sheet, and a Suggested Vent Placement Guide.
Installation Instructions
OUTER Rib Mount Installation (#52957-O).pdf
File Size: 3752 kb
File Type: pdf
Download File

Suggested Vent Placement Guide
Con-vents® Suggested Vent Placement Guide.pdf
File Size: 3711 kb
File Type: pdf
Download File

Picture
​PARTS LIST:
  • Two (2) Galvanized metal louver panels with 2” louvers & mounting flanges bent to conform to standard container wall corrugations.
  • Two (2) Perforated aluminum screens bent as above.
  • Twelve (12) Stainless Steel mounting screws
  • Twelve (12) Stainless Steel fender washers.
  • Twelve (12) Stainless Steel locknuts with nylon inserts.
  • Installation Instruction Sheet.
  • Suggested Vent Placement Guide.




OUTER RIB MOUNT
​
Style #52957-O
​Patent Pending
Indicate Quantity in Cart
Install on the outer "rib" of the wall corrugations, looking on the outside of the container.
The OUTER RIB MOUNT style is recommended for most vent installations for the following reasons;
  • It installs on an outer rib of the wall corrugations, which typically is less dented than an inner rib. 
  • Since it installs on an outer rib, air can move up the channel of the rib on the inside of the container. Which means even if you have your container packed to the walls with stuff the vents will continue to move air.
  • Cutting the hole for this vent is easier, and quieter, since you will be cutting it on the outside of the container where it will be easier to see while setting up and cutting, and not echoing the noise created by cutting the hole.
Installation Instructions
OUTER Rib Mount Installation (#52957-O).pdf
File Size: 3752 kb
File Type: pdf
Download File

Con-Vents™ Outer Rib Mount Vertical Container Vent
​PARTS LIST:
  • One (1) Galvanized metal louver panel with 2” louvers & mounting flanges bent to conform to standard container wall corrugations.
  • One (1) Perforated aluminum screen bent as above.
  • Six (6) Stainless Steel mounting screws
  • Six (6) Stainless Steel fender washers.
  • Six (6) Stainless Steel locknuts with nylon inserts.
  • Installation instruction sheet.


INNER RIB MOUNT
Style #52957-I​
​Patent Pending

Indicate Quantity in Cart
​Install on the inner "rib" of the wall corrugations, looking on the outside of the container.
The INNER RIB MOUNT style is recommended for containers used for jobsite storage or other uses that may subject the louvers to damage. It installs on an inner rib of the wall corrugations so the louvers will be more protected from damage by the outer ribs on each side of it. However, it is a little bit harder to install for the following reasons;
  • The inner ribs of the corrugated walls are typically a lot more dented than the outer ribs since the interior has been subjected to repeated loading and unloading of cargo in the container's past life. 
  • Cutting the hole for vents on a dented rib gets a little tricky because the metal in the dent wants to return to it’s original shape so cutting needs to be done more carefully.
  • Since you will be cutting the hole from the inside of the container, you will need a light source to safely see what you are doing. And the noise from cutting the hole will echo within the container, which really isn’t an issue since you’re supposed to be wearing hearing protection anyway.
Installation Instructions
INNER Rib Mount Installation (#52957-I).pdf
File Size: 3719 kb
File Type: pdf
Download File

Con-Vents™ Inner Rib Mount Vertical Container Vent
​PARTS LIST:
  • One (1) Galvanized metal louver panel with 2” louvers & mounting flanges bent to conform to standard container wall corrugations.
  • One (1) Perforated aluminum screen bent as above.
  • Six (6) Stainless Steel mounting screws
  • Six (6) Stainless Steel fender washers.
  • Six (6) Stainless Steel locknuts with nylon inserts.
  • Installation instruction sheet.​


DOOR MOUNT
Style #52957-D
​Patent Pending

Indicate Quantity in Cart
​Install on the flat surface of container doors.
​

Mount these DOOR VENTS as high as possible on the door where the louvers are less likely to be damaged. Using this vent in conjunction with the wall style vents maximizes air flow. It most likely wouldn’t be blocked by contents of the container.
Installation Instructions
DOOR Mount Installation (#52957-D).pdf
File Size: 3626 kb
File Type: pdf
Download File

Con-Vents™ Door Mount Vertical Container Vent
​PARTS LIST:
  • One (1) Galvanized metal flat louver panel with 4” louvers.
  • One (1) Perforated aluminum flat screen.
  • Six (6) Stainless Steel mounting screws
  • Six (6) Stainless Steel fender washers.
  • Six (6) Stainless Steel locknuts with nylon inserts.
  • Installation instruction sheet.


Con-Vents® also offers a reusable metal template to make vent installation on the corrugated side walls of a container a lot quicker and easier.  ​This template is for the 52957-O and 52957-I Styles only.
INSTALLATION TEMPLATE
Style #52957-T
Installation Template

We offer a reusable metal template to make vent installation, on the corrugated side walls of a container, a lot quicker and easier.

This template is for the 52957-O and 52957-I Styles only, NOT for Door Mount vents.

NOTE TO VOLUME INSTALLERS:
With each order of 30 or more vents, one template will be included with the order at no charge, if requested.
Picture


BULK PURCHASING
    12 Outer Rib Vents 
    for $480.00

     Style #52957-OB
Compared to Kit Pricing,
​Bulk Purchasing saves you $54 when you order 12 vents, ​reducing your cost to just $40 each.
​
For even more savings,
​Bulk Purchasing is available
​in quantities of 12, 14, 16, 18, 20, 22 or 24 vents.
 

Every Bulk Purchase Order
includes one (1) free
Installation Template.
OUTER RIB VENTS - Bulk Purchase
Choose the quantity you want from the drop-down menu before clicking "Add to Cart"
Want a mix of different styles instead of all Outer Rib Vents?
​
​​PLEASE NOTE: 
The order button above ​is only for the OUTER RIB style vent.
​To mix styles, follow the directions below:
​
** To order a mix of different vent styles at Bulk Purchase pricing,

SEND AN EMAIL TO [email protected] and tell us how many you want of each style you wish to purchase. Once we receive your email, we'll customize your order and send you a customized invoice to your email address before we ship.
Minimum Purchase for Bulk Purchasing is 12 vents, any one or any mix of styles. 

And as with all of our pricing, fast shipping is included.


Picture
PayPal Logo
Con-Vents® are Made in the USA by a US Veteran in the very small town of Georgetown, California.
© 2021 Con-Vents®    All Rights Reserved.     Patent Pending.
Website by TegneLink Design